Zytel® HTNFR52G35NHF BK337(PRELIMINARY)
HIGH PERFORMANCE POLYAMIDE RESIN
PA6T/66-GF35 FR(40)
CHARACTERISTICS
Regional availability
- Global
Additives
Flame retardant
Special characteristics
Flame retardant
PRODUCT TEXT
Zytel® HTNFR52G35NHF BK337 is a 35% Glass Reinforced, Flame Retardant, Non-Halogenated, PPA, High Performance Polyamide with Improved Flow
PRODUCT INFORMATION
DRY/COND.
TEST NORM
Resin Identification
PA(6T/66)-GF35FR(40)
ISO 1043
Part Marking Code
>PA(6T/66)-GF35FR(40)<
ISO 11469
Part Marking Code
>PPA-GF35FR<
SAE J1344
ISO designation
ISO 16396-PA6T/66,GF35 FR(40),M1CF1G,S10-120
-
RHEOLOGICAL PROPERTIES
DRY/COND.
UNIT
TEST NORM
Molding shrinkage, parallel
0.3/-
%
ISO 294-4, 2577
Molding shrinkage, normal
0.9/-
%
ISO 294-4, 2577
MECHANICAL PROPERTIES
DRY/COND.
UNIT
TEST NORM
Tensile Modulus
12800/-
MPa
ISO 527-1/-2
Stress at break
135/-
MPa
ISO 527-1/-2
Strain at break
1.4/-
%
ISO 527-1/-2
Flexural Modulus
11200/-
MPa
ISO 178
Flexural Strength
200/-
MPa
ISO 178
Charpy notched impact strength, 73°F
8/-
kJ/m2
ISO 179/1eA
Charpy notched impact strength, -22°F
8/-
kJ/m2
ISO 179/1eA
Poisson's ratio
0.33/-
-
-
THERMAL PROPERTIES
DRY/COND.
UNIT
TEST NORM
Melting temperature, first heat
310/*
°C
ISO 11357-1/-3
Temp. of deflection under load, 260 psi
283/*
°C
ISO 75-1/-2
RTI, electrical, 30mil
140
°C
UL 746B
RTI, electrical, 60mil
140
°C
UL 746B
RTI, electrical, 120mil
140
°C
UL 746B
RTI, impact, 30mil
115
°C
UL 746B
RTI, impact, 60mil
115
°C
UL 746B
RTI, impact, 120mil
120
°C
UL 746B
RTI, strength, 30mil
125
°C
UL 746B
RTI, strength, 60mil
125/*
°C
UL 746B
RTI, strength, 120mil
130
°C
UL 746B
FLAMMABILITY
DRY/COND.
UNIT
TEST NORM
Burning Behav. at 60mil nom. thickn.
V-0/*
class
IEC 60695-11-10
Thickness tested
1.5/*
mm
IEC 60695-11-10
UL recognition
yes/*
-
UL 94
Burning Behav. at thickness h
V-0/*
class
IEC 60695-11-10
Thickness tested
0.75/*
mm
IEC 60695-11-10
UL recognition
yes/*
-
UL 94
Oxygen index
33/*
%
ISO 4589-1/-2
Glow Wire Flammability Index, 120mil
960/-
°C
IEC 60695-2-12
Glow Wire Ignition Temperature, 120mil
775/-
°C
IEC 60695-2-13
FMVSS Class
B
-
ISO 3795 (FMVSS 302)
Burning rate, Thickness 1 mm
<80
mm/min
ISO 3795 (FMVSS 302)
ELECTRICAL PROPERTIES
DRY/COND.
UNIT
TEST NORM
Relative permittivity, 100Hz
4.3/-
-
IEC 62631-2-1
Relative permittivity, 1MHz
3.9/-
-
IEC 62631-2-1
Dissipation factor, 100Hz
50/-
E-4
IEC 62631-2-1
Dissipation factor, 1MHz
110/-
E-4
IEC 62631-2-1
Electric strength
31/-
kV/mm
IEC 60243-1
Dielectric Constant, 1 GHz
3.9/-
-
ASTM D 2520 B
Dielectric Constant, 10 GHz
3.9/-
-
ASTM D 2520 B
Dissipation Factor, 1 GHz
110/-
E-4
ASTM D 2520 B
Dissipation Factor, 10 GHz
104/-
E-4
ASTM D 2520 B
OTHER PROPERTIES
DRY/COND.
UNIT
TEST NORM
Density
1490/-
kg/m3
ISO 1183
INJECTION
DRY/COND.
UNIT
Drying Recommended
yes
Drying Temperature
100
°C
Drying Time, Dehumidified Dryer
6 - 8
h
Processing Moisture Content
≤0.1
%
Min. melt temperature
320
°C
Max. melt temperature
325
°C
Min. mold temperature
90
°C
Max. mold temperature
130
°C
PROCESSING
Injection molding
For molding machine components, use corrosion resistant and wear resistant steel. For details please contact your DuPont representative. Limit the residence time of the resin in the machine. Use proper protective equipment and adequate ventilation.